Typical Applications
  Motors, Hermetic Motors
  Dry-type transformers
  Automotive alternators
  Torroidal Coils
  Solenoids

Product Description
Thermal Class:
  200° (copper)
  220° (aluminum)

Super Hyslik 200 includes a proprietary internal lubricating system to aid windability and insertion.

Tough, abrasion-resistant surface which withstands damage from automated winding operations and insertion.

Excellent dielectric performance.

Superior chemical and moisture resistance, especially with refrigerants in hermetic applications.

Superior thermal overload protection, especially during locked-rotor conditions.

GENERAL INFORMATION
References Are Provided for Comparative Purposes:

Round
  NEMA: Copper MW 35-C, MW 73-C
  NEMA: Aluminum MW 35-A, MW 73-A
UL: File # E37683

Square & Rectangular
  NEMA: MW 36-C (Cu)
UL: File # E37683

Availability:
  
Round
      Copper
 
      Single 14 - 38 AWG
      Heavy   4 - 37 AWG
      Quad   14 - 21 AWG

      Aluminum
      Single 14 - 24 AWG
      Heavy 6 - 24 AWG

   Square
      Copper
      Heavy 1 - 14 AWG

   Rectangular   Copper (Heavy)

      Min Width .081"
  Max Width .750"
  Min Thickness .030"
  Max Thickness .292"

 

Typical Properties

This data is typical of 18 AWG copper, heavy build insulation only. It is not intended to be used to create specification limits.


THERMAL

 

Thermal Endurance
20,000 hr Life >210°C

Thermoplastic Flow
min : 300°C
typical : 350°C

Heat Shock (20% 3x)
½ hr @ 220°C min : no cracks
½ hr @ 240°C min : no cracks

Solderability
@ 480°C (900° F) : No

Stress Relief Temp:  160°C

MECHANICAL 

Mandrel Flexibility
After Elongation
    min : 20% 3x OK
    typical : 30% 1x OK
After Snap
    min : 3x OK
    typical : 1x OK
 

Unilateral Scrape
Avg of 3 sides
    min : 1150 gms
    typical : 1700 gms
 

Repeated Scrape
700 gms
    min : 60 strokes
    typical : 100 strokes
 

Dynamic C of F    typical: 0.046 

ELECTRICAL 

Dielectric Breakdown
@ RT : 11 kV
@ 200°C : 7.0 kV

High Voltage DC Continuity
NEMA @ 1500 V DC : 5 faults/100 feet max
Typical @ 3000 V DC : 0-1 faults/100 feet

Corona Inception Voltage
typical: 580V

CHEMICAL 

Retained Dielectric
After 72 hrs exposure to R-22 +300°C conditioning: 3.5kV
 

R-22 Extractables:  0.8%
 

Resistance to Solvents
after 24 hrs @ RT : Pass
Solvents Including:
Xylene,
50/50 Cellosolve/Xylene,
Perchloroethylene,
1% NaOH,
28% Sulfuric Acid,
Gasohol 


Procedure followed to determine published values:

NEMA: National Electrical Manufacturers Association
JIS: Japanese Industrial Standards
IEC: International Electrotechnical Commission
ASTM: American Society for Testing and Materials

Download pdf Spec Sheet Super Hyslik 200